Phase Neutral Circui …

Phase Neutral Circui …

د.م. 38,00

SKU: N/A Category:

Description

Phase Neutral Circuit breaker from Legrand, the DNX³ 4500 6kA, has been released to the public. The breaker boasts a thermal-magnetic design with positive contact for greater safety and protection. It also features an auto/auto input and output terminal for easier and faster installation. Additionally, it has a voltage presence test for greater reliability. The 32 A breaker is designed to withstand up to 6 kA of current and is available in corner C with screw/screws from Amazon.de.

Phase Neutral Circuit High quality

The Legrand 16 A  Phase Neutral Circuit breaker is a reliable solution that provides ample protection against power surges and other hazardous conditions. The breaker is designed with a curve C design which allows it to detect voltage presence with flying test, further enhancing its safety features. The breaker is certified to handle up to 6 kA of current, making it suitable for most residential and commercial applications.

The DNX³ 4500 6kA is an ideal choice for any home or business looking for reliable protection against power surges and other hazardous conditions. With its thermal-magnetic design and positive contact, it offers superior protection against power problems while providing easy installation due to its auto/auto input and output terminals. With its voltage presence test, it is guaranteed to provide reliable safety features in any application.

Technology:

. Limiting device

. The Neutral contact closes before and opens after the Phase contact

. The Phase pole provides protection and isolation for the Phase circuit

. The neutral pole provides isolation for the Neutral circuit

RANGE Polarity:

. 2 poles including 1 protected pole and 1 neutral pole

Width:

. 1 module (17.8 mm)

Rated currents In:

. 2 / 6 / 10 / 16 / 20 / 25 / 32 A , C curve

. 10 / 16 / 20 / 25 A, D curve

Magnetic tripping curves:

. C curve (between 5 and 10 In)

. D curve (between 10 and 14 In)

Rated voltage and frequency:

. 230 V ~, 50 Hz with standard tolerances

. 240 V ~, 50 Hz with standard tolerances

Breaking capacity:

. Icn = 4500 A in accordance with standard EN/IEC 60898-1

. Icu = 4,5 kA in accordance with standard EN/IEC 60947-2

Technical data sheet: F01291EN/00